• Phone

    86-21-57632436

  • Address

    Rm 612-613, No 76, Jiuxin Road, Jiuting Town, Songjiang District, Shanghai, China

  • E-mail

    k@waimaotong.com

LatestProducts

                            Clamp-on Ultrasonic Flow Meter (CX-TDS)

Clamp-on Ultrasonic Flow Meter (CX-TDS)

meter ultrasonic
INQUIRY PRECISE INQUIRY
Description

Basic Info
  • Model NO.: CX-TDS
  • Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
  • Sensor: Flange,Thread,Insertion
  • Type: Ultrasonic Flow Meter
  • Measuring Principle: Ultrasonic
  • Certification: CE, SGS, ISO
  • Max Size: 6000mm
  • Certificate: ISO,CE,SGS
  • Specification: CE/SGS/ISO
  • HS Code: 9026100000
  • Accuracy: ±0.6-1%
  • Size: </=Dn6000
  • Application: Industrial Production
  • Measuring Media: Liquid
  • Measurement Object: Closed Pipe or Open Pipe
  • Max Temp: 160c
  • Output and Communitaion: Pulse,4-20mA,RS485,RS232
  • Trademark: GN
  • Origin: Shanghai China
Product Description
1&period;Brief introduction of CX-HUFM-TDS-100H Handable ultrasonic flowmeter
1&period;Widely used to measure liquid flow in various industries
2&period;Smart body&comma; high accuracy&comma; good repeatability&comma;long-running cell&comma;easy operation&comma;built-in printer etc&period;
3&period;Very popular in industry like petrochemical&comma; water&comma; power&comma; energy monitoring etc&period; It's
4&period;Exported to Japan&comma; Korea&comma; Australia&comma; America etc&period;
 
Main features
1&period;Accuracy&colon;±1&percnt;
2&period;Repeatability&colon;±0&period;2&percnt;
3&period;Easy to install outside the pipe
4&period;Four line display&colon; Instantaneous flow rate&comma;Accumulate flow&comma;status
5&period;Standard interface RS232 for data output and on-line operation
6&period;Self-diagnose to show the current status
7&period;Built-in Nickel-hydrogen cell supports 10 hours of operation
Sensor S1Z M1Z S1 M1 L1 S1H M1H
Pipe size&lpar;DN&rpar; 15-100 50-700 15-100 50-700 300-6000 15-100 50-700
Material Material ABS Special material for H -temp
Frequency 1MHz
Installation V&lpar;N&sol; W&rpar; V&sol; Z V&lpar;N&sol; W&rpar; V&sol; Z Z V&sol;&lpar;N W&rpar; V&sol; Z
Calibration Calibrated together with flowmeter
Magnetic yes no
Temperature 0-70 0-160
IP IP65
Outline size 200&ast;25&ast;25 200&ast;40&ast;40 45&ast;30&ast;30 60&ast;45&ast;45 80&ast;70&ast;55 90&ast;85&ast;24 90&ast;82&ast;29
N&period;W&period; g&sol;2pcs 250 1080 75 250 650 94 150
Medium Water sea water sewage Alcohol oil etc
Turbidity≤ 10000ppm with little air bubble
Pipe Carbon steel stainless steel cast iron Brass PVC Aluminum etc&period;
Pipe liner Rubber Slurry PP PS bakelite&comma; PTFE
Signal cable standard 5M &ast;2 optional&colon;10M&ast; 2 or 15M&ast; 2

2&period;Main features of CX-UFM-TDS-100M Ultrasonic Modular Flowmeter
1&period;It can work alone without a LCD and keypad module
2&period;no pressure drop&comma; no moving parts&comma; no leaks and no contamination
3&period;Integrate the modules into a multi-channel flow meter then can measures several dozen of different pipes
4&period;Higher accuracy by measures the same pipe with all the channels
5&period;Easy to install it and don't need special skills or tools
 
Technical parameters
Display&colon; 2x10 LCD indicator to display flow rate&comma; flow speed&comma; total flow
Operation To set with 4 touch keys
Accuracy Better than 1&percnt; accuracy  and  0&period;2&percnt; of repeatability
Application Positive&sol;negative&sol;net flow or heat totaliser
Protocol MODBUS&sol;MBUS protocol
Input 4~20mA&sol;PT100 platinum resistance input
Output OCT&lpar;Pulse width 6~1000ms&comma; default&colon; 200ms&rpar; RS-485&sol;4~20mA output&sol;relay
Power 24VDC for module&comma;85~264VAC&sol;24VDC for display terminal
Protection IP57
Software can be upgrated with code-documents sent by email
Memory 512 days&sol;120month&sol;10years forward-flow &sol; return-flow &sol; Net-flow
Note&colon;The memory will be kept in case of power lost

Sensor S1 type M1 type L1 type S1H M1H
Pipe size&lpar;DN&rpar; 15-100 50-700 300-6000 15-100 50-700
Material ABS Special material for H -temp
Frequency 1MHz
Installation V&lpar;N&sol; W&rpar; V&sol; Z Z V&sol;&lpar;N W&rpar; V&sol; Z
calibration Calibrated together with flowmeter
magnetism Magnetic No magnetic
Temperature 32ºF~158ºF&lpar;0-70ºC&rpar; 32ºF~320ºF&lpar;0-160ºC&rpar;
Protection class IP65
Dimension&lpar;mm&rpar; 45&ast;30&ast;30 60&ast;45&ast;45 80&ast;70&ast;55 90&ast;85&ast;24 90&ast;82&ast;29
Weight&lpar;g&rpar; 75 250 650 94 150
Liquid types Water&period; Sea water waste water&period; Chemical liquids&period; oil&comma; crude oil&period; alcohol&period; beer&period; etc
Suspension concentration ≤20000ppm&period;may contain very small amount of air bubbles
Pipe material All metals' most plastics&comma; fiber glass etc
Transducer cable Standard length 5 meter×2&period;can be extended to 10 meter×2 or 15meter×2


3&period;Main features of CX-UFM-TDS-100P portable type ultrasonic flowmeter
1&period;Easy to install outside the pipe
2&period;High accuracy ±1&percnt;&comma; good repeatability&colon;±0&period;2&percnt;
3&period;Long-running cell&comma;easy operation&comma;built-in printer etc
4&period;two lines display&colon; Instantaneous flow rate&comma;Accumulate flow&comma;status
5&period;Built-in printer&comma;to print in time and regularly
6&period;Standard interface RS485 for data output and on-line operation
7&period;Self-diagnose to show the current status
8&period;Built-in Nickel-hydrogen cell supports 20 hours of operation
 
Technical parameters
Sensor S1 M1 L1 S1H M1H
Pipe size&lpar;DN&rpar; 15-100 50-700 300-6000 15-100 50-700
Material ABS Special material for H -temp
Frequency 1MHz
Installation V&lpar;N&sol; W&rpar; V&sol; Z Z V&sol;&lpar;N W&rpar; V&sol; Z
calibration Calibrated together with flowmeter
magnetism Magnetic No magnetic
Temperature 32ºF~158ºF&lpar;0-70ºC&rpar; 32ºF~320ºF&lpar;0-160ºC&rpar;
Protection class IP65
Dimension&lpar;mm&rpar; 45&ast;30&ast;30 60&ast;45&ast;45 80&ast;70&ast;55 90&ast;85&ast;24 90&ast;82&ast;29
Weight&lpar;g&rpar; 75 250 650 94 150
Liquid types Water&period; Sea water waste water&period; Chemical liquids&period; oil&comma; crude oil&period; alcohol&period; beer&period; etc
Suspension concentration ≤10000 ppm with little air bubble
Pipe Carbon steel stainless steel cast iron Brass PVC Aluminum etc&period;
Pipe liner Rubber Slurry PP PS bakelite&comma;PTFE
Signal cable Standard&colon;5M&ast; 2 optional&colon;10M&ast; 2 or 15M &ast;2


4&period;Brief introduction of CX-UWM-TDS-100W  Ultrasonic water meter
1&period;Designed according to Europe alliance EN1434 standard and ultrasonic time-difference principle
2&period;Ultrasonic time-difference principle Measuring water or other liquid
3&period;High accuracy&comma; better reliable&comma; no moving part&comma; no need to set data&period; Install in any angle
4&period;It can instead of other water meter
 
Main features
1&period; Accuracy&colon; ±1&percnt;&comma;± 2&percnt;&comma;Repeatability&colon; ±0&period;5&percnt;
2&period;Measurement cycle&colon; Default for 3S&comma; 1~31S should be optional by the user
3&period;Battery can work 6-10years&comma; or two line power
4&period;Lowest measuring velocity of liquid 0&period;01m&sol;s
5&period;No pressure lost and moving parts&comma; no nursing for 10 years
6&period;Pipe length designing according to the normal water meter
7&period;IP68&comma; can working under water lower than 2 meters
8&period;Foundry in mould&comma; no leakage
9&period;Ceramic sensor apply to -40ºC~160ºC
10&period;Over look type&comma; normal type&comma; separate type
 
Technical parameters
Pipe ID &lpar;mm&rpar; Lowest Flowrate
Detectable
Min&period;Flowrate
qmin
Boundary Flowrate
qt
Max&period;Flowrate
qmax
Cumulative Flowrate
&lpar;m3&rpar;
&lpar;m3&sol;h&rpar; Max Min
15 0&period;0019 0&period;0238 0&period;072 1&period;5 99999&period;999 0&period;001
20 0&period;0019 0&period;0238 0&period;072 2&period;5
25 0&period;0045 0&period;056 0&period;169 3&period;0
32 0&period;0073 0&period;092 0&period;275 12
40 0&period;0114 0&period;144 0&period;429 20
50 0&period;0353 0&period;35 2&period;1 150 9999999&period;9 0&period;1
65 0&period;06 0&period;60 3&period;58 180
80 Single-path 0&period;09 0&period;9 5&period;43 230
Double-path 0&period;063 0&period;9 5&period;43 230
100 Single-path 0&period;141 1&period;41 8&period;48 300
Double-path 0&period;099 1&period;41 8&period;48 300
125 Single-path 0&period;221 2&period;21 13&period;25 360
Double-path 0&period;155 2&period;21 13&period;25 360
150 Single-path 0&period;318 3&period;18 19&period;08 460
Double-path 0&period;223 3&period;18 19&period;08 460
200 Single-path 0&period;565 5&period;6 33&period;93 660
Double-path 0&period;396 5&period;6 33&period;93 660
4-path 0&period;226 5&period;6 33&period;93 660
250 Single-path 0&period;883 8&period;83 53&period;0 740
Double-path 0&period;618 8&period;83 53&period;0 740
4-path 0&period;353 8&period;83 53&period;0 740